Solar Energy Lead-Acid Batteries for UPS/Telecom/Data Center/Emergency Lighting 12V200ah Amaxpower

Product Details
Customization: Available
Type: AGM Lead Acid Battery
Usage: Car, UPS, Electric Power, Lighting, Electric Bicycle, Boat
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2023

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Management System Certification
ISO 9001, ISO 14001, OHSAS/ OHSMS 18001, SA 8000
OEM/ODM Availability
Yes
  • Solar Energy Lead-Acid Batteries for UPS/Telecom/Data Center/Emergency Lighting 12V200ah Amaxpower
  • Solar Energy Lead-Acid Batteries for UPS/Telecom/Data Center/Emergency Lighting 12V200ah Amaxpower
  • Solar Energy Lead-Acid Batteries for UPS/Telecom/Data Center/Emergency Lighting 12V200ah Amaxpower
  • Solar Energy Lead-Acid Batteries for UPS/Telecom/Data Center/Emergency Lighting 12V200ah Amaxpower
  • Solar Energy Lead-Acid Batteries for UPS/Telecom/Data Center/Emergency Lighting 12V200ah Amaxpower
  • Solar Energy Lead-Acid Batteries for UPS/Telecom/Data Center/Emergency Lighting 12V200ah Amaxpower
Find Similar Products
  • Overview
  • Product Description
  • OEM & ODM
  • Applications
  • Company Profile
  • Factory Tour
  • Certifications
  • FAQ
Overview

Basic Info.

Model NO.
GM12-200
Nominal Voltage
12V
Discharge Rate
Low Discharge Rate
Shape
Square Battery
Electrolyte
Acid
Installation
Fixed
Rechargeable
Chargeable
Model
AGM Battery 12V200ah
Capacity
200ah Solar Battery
Size
522*240*216*240mm
Weight
60kg
Color
Gray, Yellow or OEM
OEM/ODM
Yes
Material
High Pure Lead 99.9997%
Case
ABS
Self-Discharge
Less Than 3%
Design Life
8-10years
Transport Package
Carton/ Pallet
Specification
agm solar battery 12v200ah
Trademark
AMAXPOWER / OEM
Origin
China
HS Code
8507200000
Production Capacity
100000PCS/Month

Packaging & Delivery

Package Size
53.20cm * 25.00cm * 26.00cm
Package Gross Weight
60.500kg

Product Description

Product Description

Solar Energy Lead-Acid Batteries for UPS/Telecom/Data Center/Emergency Lighting 12V200ah Amaxpower
AMAXPOWER GM Series Durable VRLA AGM Battery For UPS System and Solar Storage
AMAXPOWER GM Series VRLA AGM Battery, also known as VRLA battery, SLA batteries and SMF battery, is free maintenance sealed lead acid batteries designed with AGM technology. High performance plates and electrolyte give extra power output for common power backup system, widely used in the fields of UPS, Security and Emergency lighting system.

Features and Advantages
1. Absorbent Glass Mat (AGM) technology, good quality AGM separator, increase battery service life.
2. High purity raw material, low self-discharge rate, long life expectancy of 10 years in floating condition.
3. Wide operating temperature range from -15°C to 45°C.
4. Heat sealing technique instead of glue sealing, to increase the tightness and stability of battery.
5. Unique corrosion resistance grid alloy, long service life, maintenance-free operation.
6. Tight assembly technology, high efficiency discharge performance.

Product Parameters
 
Nominal Voltage  12V (6 cells)
Nominal Capacity 200Ah@10 hour-rate 
Dimension Length 522±2(20.6 inches)
Width 240±2(9.45 inches)
Height 218±2(8.58 inches)
Total Height 225±2(8.86 inches)
Weight Approx. 58.5kg (129lbs)
Reference Capacity (25°C/77°F ) 20 hour rate (10.5A) 210Ah
10 hour rate (20A) 200Ah
5 hour rate (36A) 180Ah
3 hour rate (53.3A) 160Ah
1 hour rate (130A) 130Ah
Max. Discharge Current (25°C/77°F) 1200A (5S)
Internal Resistance Full charged at 25ºC(77°F)Approx. 3.8mΩ
Charge (Constant Voltage) (25°C/77°F)

Cycle Use

Voltage: 14.4-15.0V

Initial Charging Current: Less than 50A

Float Use Voltage: 13.6-13.8V
Operating Temperature Range Discharge -20~50°C
Charge 0~50°C
Storage  -20~50°C
Nominal Operating Temperature Range 25°C ±3°C(77±3°F)

Capacity affected by Temperature

(20 hour rate)

40°C(104°F) 102%
25°C(77°F) 100%
0°C(32°F) 85%
-15°C(5°F) 65%
Self-Discharge (25°C/77°F) After 3 month 91%
After 6 month 82%
After 12 month 64%
Container Material ABS Plastic
Solar Energy Lead-Acid Batteries for UPS/Telecom/Data Center/Emergency Lighting 12V200ah AmaxpowerSolar Energy Lead-Acid Batteries for UPS/Telecom/Data Center/Emergency Lighting 12V200ah Amaxpower
 

OEM & ODM

We Provide OEM&ODM service to both domestic and international clients. Our experience in R&D and manufacturing can help you produce best products with your own brand.
Solar Energy Lead-Acid Batteries for UPS/Telecom/Data Center/Emergency Lighting 12V200ah Amaxpower
Internal Structure
  1. Negative plate - Balanced Pb-Ca grid for improved recombination efficiency
  2. Separator - Advanced AGM separator for high pressure cell design
  3. Positive plate - Thick high Sn low Ca grid with special paste
  4. Battery container and cover -Fire resistance ABS, water proof
  5. Electrolyte - Dilute high purity sulfuric acid
  6. Relief valve - Complete with integrated flame arrestor

Applications

Solar Energy Lead-Acid Batteries for UPS/Telecom/Data Center/Emergency Lighting 12V200ah Amaxpower-Solar & Wind energy storage system          -Solar street lights                           -Off-grid energy storage                      -Household energy storage   
-Telecom backup system                              -Mobile base stations                      -Uninterruptible power system            -Grid load shifters
-Emergency backup system                         -UPS Systems                                 -Control System                                  -Power Tools                            
-Aerial work platform                                    -Floor cleaning machine                  -Golf cart and Buggies                        -Electric vehicles          
-Electric forklifts                                            -
Medical equipment                         -Marine equipment, etc...

Company Profile

Solar Energy Lead-Acid Batteries for UPS/Telecom/Data Center/Emergency Lighting 12V200ah AmaxpowerAMAXPOWER NEW ENERGY TECH Co., Ltd, founded in 2005, has steadily expanded to approximately 1,000 employees, including an experienced management team and manufacturing team that has been at the forefront of manufacturing technology in the battery field.
AMAXPOWER is located ina 50,000-square-meter modern industrial park in Guangdong, China, with first-class production facilities and an annual production capacity of approximately 2 ,000,000kVAh.
As a professional manufacturer and high-tech enterprise of lead acid battery in China, we produce full range of valve regulated lead acid (VRLA) batteries, including AGM Batteries, Gel Batteries, Deep Cycle Batteries, Front Terminal Batteries, OPzV Batteries, OPzS Batteries, LiFePO4 Batteries and Solar Panel and so on. The products are widely used in communication electricity, lighting, UPS, telecom system, and other basic industries; Solar energy, wind energy, smart grid, electric vehicles, energy storage battery station, and other strategic emerging industries.

Our Advantages

* 17+ years industrial experience with advanced equipment and instruments and builds Automatic production line.
* Strictly comply with ISO quality management system, products have passed CE,IEC,ROHS and other certifications.
* We provide OEM & ODM and advanced customization services to over 100 countries. A professional marketing and technical team with more than 1000 employees provide you thoughtful services.
* Fast delivery, less than 7 days for 
stock products.

Factory Tour

Battery Production
-------------------------------------------------------------------------------------------------
Solar Energy Lead-Acid Batteries for UPS/Telecom/Data Center/Emergency Lighting 12V200ah Amaxpower

Quality Control
-------------------------------------------------------------------------------------------------
Solar Energy Lead-Acid Batteries for UPS/Telecom/Data Center/Emergency Lighting 12V200ah Amaxpower
QC Process
1. In order to ensure battery's quality, the lead plate must pass pure 99.9999%.
2. Battery Case Testing - Anti-impact/prevent burst.
3. Acid filling - Measure the weight - Ensure the consistency of each battery.
4. Online control - Rigorous monitoring status and deep cycle testing.
5. Each battery testing before shipment. Guarantee 100% pass rate.

Packing and Shipping
-------------------------------------------------------------------------------------------------
Solar Energy Lead-Acid Batteries for UPS/Telecom/Data Center/Emergency Lighting 12V200ah Amaxpower

Our Project
-------------------------------------------------------------------------------------------------

Solar Energy Lead-Acid Batteries for UPS/Telecom/Data Center/Emergency Lighting 12V200ah Amaxpower

Certifications

Solar Energy Lead-Acid Batteries for UPS/Telecom/Data Center/Emergency Lighting 12V200ah Amaxpower

FAQ

Q1. Are you a battery manufacturer, and do you produce the plate by yourself?
A: Yes, we are a professional battery manufacture with more than 17years experience in Guangdong Province, China. And we produce plates by ourselves.

Q2. How about the delivery time usually?
A: About 7 days for stock products, around 20 days for half container products, 30 days for 20ft full container products.

Q3. Can you print my logo on the batteries?
A: Yes, you can print your logo on our batteries when you order reach 20ft container quantity. If not, price will be negotiated.

Q4. Can your battery be delivered by sea and air?
A: Yes, our batteries can be delivered both by sea and by air. We have MSDS, test report for safe transport as non-dangerous products.

Q5. What certificate your company have?
A: ISO 9001, ISO 14001, ISO45001,  CE, IEC 61427 test report, and other Chinese honor.
Q6. How does your factory control the quality?
A: We Adopt ISO 9001 quality system to control the quality. We have Incoming Quality Control (IQC) department to test and confirm raw material meets high quality producing requirements; Production Quality Control (PQC) department contains The first Inspection, In-process quality control, acceptance inspection and full inspection; Outgoing Quality Control (OQC) department confirm no defective batteries come out from the factory.

Q7. Is it 10HR or 20HR?
A: For 4AH to 17AH battery: 20HR, 24AH to 250AH battery: 10HR
Q8. Why battery has different capacity at different hour rate?
A: The capacity of a battery, in Ahs, is a dynamic number that is dependent on the discharge current. For example, a battery that is discharged at 10A will give you more capacity than a battery that is discharged at 100A. With the 20-hr rate, the battery is able to deliver more Ahs than with the 2-hr rate because the 20-hr rate uses a lower discharge current than the 2-hr rate.
Q9. What is your warranty time for VRLA battery?
A: It depends on battery capacity, depth of discharge, and battery usage. Please kindly contact us for accurate information based on detailed requirements.

Q10. What is the shelf life of VRLA battery and how to maintain the battery?
A: The limiting factor of battery's shelf life is the rate of self-discharge which itself is temperature dependent. VRLA batteries will self-discharge less than 3% per month at 77° F (25° C). VRLA batteries should not be stored for more than 6 months at 77° F (25° C) without recharged. If in hot temperature, recharge it every 3 months. When batteries are taken out of long storage, it is recommended to recharge before use.

Q11. Can I fast charge my battery?
A: Fast charging is not recommended as ifs harmful for the battery.
Q12. Can I do a partial replacement of my batteries?
A: Partial battery replacement of lead acid battery banks is not recommended.

Q13. If battery damage, how will you solve the problem?
A: If there is problem happened, we will gather all the picture and according to your using condition to find out what cause this problem. If it is producing problem, we will replace you the new one in the next shipment


Product Specifications and models
-------------------------------------------------------------------------------------------------

GM Series - General VRLA AGM Battery 
Model No. Voltage(V) Capacity (AH) Approx Weight Dimensions Termminal Type
Kg lbs Length Width Height Total Height
mm inch mm inch mm inch mm inch
GM12-24 12 24 7.8 17.20 166 6.54 175 6.89 126 4.96 126 4.96 T2
GM12-33 12 33 10.0 22.00 196 7.70 131 5.16 155 6.10 180 7.09 T3
GM12-38 12 38 12.2 26.84 197 7.73 166 6.54 174 6.85 181 7.13 T2
GM12-40 12 40 13.0 28.70 197 7.73 166 6.54 174 6.85 181 7.13 T2
GM12-45 12 45 13.5 29.70 197 7.73 166 6.54 171 6.73 171 6.73 T2
GM12-50 12 50 15.0 33.07 230 9.06 138 5.43 208 8.19 212 8.35 T3
GM12-55 12 55 16.2 35.71 230 9.06 138 5.43 208 8.19 212 8.35 T3
GM12-65 12 65 20.5 45.10 350 13.80 166 6.54 179 7.05 179 7.05 T3
GM12-70 12 70 20.5 45.20 260 10.20 169 6.65 211 8.30 215 8.46 T3
GM12-80 12 80 23.4 51.50 260 10.00 169 6.65 211 8.30 215 8.46 T3
GM12-90 12 90 27.0 59.40 307 12.10 169 6.66 211 8.31 215 8.47 T3
GM12-100A 12 100 27.5 60.60 331 13.03 173 6.81 213 8.39 233 9.17 T3
GM12-100 12 100 30.0 66.00 407 16.00 174 6.85 209 8.23 233 9.17 T5
GM12-120 12 120 36.5 80.30 407 16.00 174 6.85 209 8.23 233 9.17 T5
GM12-135 12 135 41.5 91.50 341 13.44 173 6.82 282 11.11 283 11.15 T5
GM12-150 12 150 42.5 93.50 484 19.10 171 6.73 241 9.49 241 9.49 T4
GM12-180 12 180 56.5 124.00 522 20.60 240 9.45 216 8.50 240 9.45 T4
GM12-200 12 200 60.0 132.00 522 20.60 240 9.45 216 8.50 240 9.45 T4
GM12-230 12 230 64.0 141.10 522 20.60 240 9.45 216 8.50 240 9.45 T4
GM12-250 12 250 73.0 161.00 520 20.50 268 10.55 220 8.66 243 9.57 T4

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
People who viewed this also viewed